Standard
EN 62395-1
Voltage Rating
230V
CABLE CONSTRUCTION
Bus wire: Nickel plated copper.
Self-regulating heating element
Insulation: Thermoplastic.
Protective: Tinned Cu braid.
Outer sheath: Thermoplastic or fluoropolymer.
Mechanical and Thermal Properties
Maximum maintenance temperature: 65℃
Maximum exposure temperature: 85℃
Minimum installation temperature: -51℃
Minimum bending radius: 25 mm
Cable Parameter
APPROX. |
Nominal output at 10℃ |
APPROX. |
---|---|---|
13.6×5.5 |
10 |
91 |
14.1×5.8 |
10 |
108 |
13.8×5.6 |
10 |
108 |
13.6×5.5 |
20 |
91 |
14.1×5.8 |
20 |
108 |
13.8×5.6 |
20 |
108 |
13.6×5.5 |
30 |
91 |
14.1×5.8 |
30 |
108 |
13.8×5.6 |
30 |
108 |
13.6×5.5 |
40 |
91 |
14.1×5.8 |
40 |
108 |
13.8×5.6 |
40 |
108 |